  "captured": "2026-11-05",
  "method": "Chromium execution; load fictional case 1, capture actual result; retain text export in this manifest. Site header hidden only in this illustration.",
  "scope": "Software execution only. No physical test, customer evidence, authenticated signature or maintenance approval.",
  "asset": "/images/aircraft-recording-fictional-run-2026-11-05.webp",
  "width": 1118,
  "height": 377,
  "sha256": "e30a5085ba9146cd8e903e0c1dcac08692df94b7fb1d8466166481e72ed41b3c",
  "inputs": {
    "recordSource": "fictional",
    "aircraftTailNumber": "DEMO-ONLY",
    "aircraftType": "Fictional training airframe",
    "workOrderNumber": "DEMO-WO-001",
    "ammReference": "EXAMPLE task / revision — unverified",
    "flightControlSystem": "Example rudder circuit",
    "cableId": "DEMO-CABLE-01",
    "cableDiameterInch": "1/8",
    "cableConstruction": "7x19 MIL-DTL-83420 Comp A (Galvanized)",
    "cableCoating": "bare",
    "ambientTemp": "72",
    "tempUnit": "F",
    "targetTensionMin": "45",
    "targetTensionNominal": "50",
    "targetTensionMax": "55",
    "measuredTension": "51.5",
    "forceUnit": "lbf",
    "measuredForceUnit": "lbf",
    "tensiometerModel": "DEMO instrument (not a product specification)",
    "tensiometerSerial": "DEMO-SN-001",
    "riserBlockId": "DEMO contact — unverified",
    "profileReference": "DEMO calibration profile — unverified",
    "calDueDate": "2027-04-15",
    "measurementDate": "2026-11-05",
    "technicianLicense": "DEMO-ID (not a signature)",
    "inspectorStamp": "",
    "spanLengthInches": "",
    "controlCyclesCompleted": true,
    "turnbuckleSafety": "ms21256_clips",
    "exposedThreadsCount": "1"
  },
  "status": "Minimum\n45 lbf\nReading\n51.5 lbf\nMaximum\n55 lbf\nDRAFT_WITHIN_ENTERED_LIMITS\nDeviation: +3% from nominal target\nEntered due date: 161 days after measurement\n\nComparison equivalent: 51.5 lbf; original reading: 51.5 lbf. Entered values are preserved.\n\nReading is inside your entered limits; the entered calibration due date is not before measurement. Next: verify source limits, profile and certificate, then review this unsigned draft in your controlled maintenance system.\n\nEntered limits must already apply at the recorded temperature. No thermal correction or AMM lookup is performed.\nSafety method and thread count are user-reported; verify acceptability against the applicable maintenance data.",
  "exportText": "UNSIGNED DRAFT — user-entered evidence only. No signature, cryptographic digest, compliance certification, audit trail or return-to-service approval. Not an ATA or vendor import format.\nFICTIONAL EXAMPLE — limits, references, instrument and personnel IDs are not approved data.\nRECORD_ID: DRAFT-DEMOONLY-DEMOWO001\nSTATUS: DRAFT_WITHIN_ENTERED_LIMITS\nrecordSource: fictional\naircraftTailNumber: DEMO-ONLY\naircraftType: Fictional training airframe\nworkOrderNumber: DEMO-WO-001\nammReference: EXAMPLE task / revision — unverified\nflightControlSystem: Example rudder circuit\ncableId: DEMO-CABLE-01\ncableDiameterInch: 1/8\ncableConstruction: 7x19 MIL-DTL-83420 Comp A (Galvanized)\ncableCoating: bare\nambientTemp: 72\ntempUnit: F\ntargetTensionMin: 45\ntargetTensionNominal: 50\ntargetTensionMax: 55\nmeasuredTension: 51.5\nforceUnit: lbf\nmeasuredForceUnit: lbf\ntensiometerModel: DEMO instrument (not a product specification)\ntensiometerSerial: DEMO-SN-001\nriserBlockId: DEMO contact — unverified\nprofileReference: DEMO calibration profile — unverified\ncalDueDate: 2027-04-15\nmeasurementDate: 2026-11-05\ntechnicianLicense: DEMO-ID (not a signature)\ninspectorStamp: [NOT PROVIDED]\nspanLengthInches: [NOT PROVIDED]\ncontrolCyclesCompleted: true\nturnbuckleSafety: ms21256_clips\nexposedThreadsCount: 1\nMeasured equivalent for comparison: 51.5 lbf\nWithin entered limits: true\nDeviation from entered nominal (%): 3\nCalendar days from measurement to due date: 161\nFIELD ERRORS:\nREVIEW WARNINGS:\nEntered limits must already apply at the recorded temperature. No thermal correction or AMM lookup is performed.\nSafety method and thread count are user-reported; verify acceptability against the applicable maintenance data.\nNEXT: Reading is inside your entered limits; the entered calibration due date is not before measurement. Next: verify source limits, profile and certificate, then review this unsigned draft in your controlled maintenance system."
}