CTM-ELV / 4 / 6 / 8 rope balance
Elevator Cable Tension Meters & Balancing Kits
Compare traction-rope loads with a portable meter or a synchronized multi-channel balancing arrangement.
START WITH YOUR ROPE
Cable diameter × tension capacity
Planning envelopes across each family. A single model does not cover every diameter and load combination. Confirm the exact rope profile, range and calibrated accuracy in your quotation.
| Model family | Supported cable diameter | Tension capacity envelope | Accuracy | Operation mode |
|---|---|---|---|---|
| CTM-ELV | 6–19 mm / 0.236–0.748 in | Up to 20 kN per rope / 4,496 lbf / 2,039 kgf | Target ±1.5–2% FS; subject to rope-specific validation | Sequential or multi-channel |
MEASUREMENT WORKFLOW
Sequential or multi-channel: define the installation first
Fix the measurement position and operating condition, label each rope, collect comparable readings, then adjust and recheck using the approved service procedure.
The requested <5% imbalance target is a project criterion, not a universal maintenance standard. Use the elevator manufacturer’s acceptance method.
What the CTM-ELV review covers
- 4, 6 or 8 rope measurement plans
- Sequential checks or simultaneous channel comparison
- Rope identification and repeatable car-position records
Send these details
- Rope count, diameter and construction
- Per-rope load and measurement position
- Required balance criterion and reporting format
Elevator installation, commissioning and maintenance engineering teams.
BUILD THE RIGHT PACKAGE
Calibration, protection & signal options
Select the accessories in the RFQ below. Budget add-ons are indicative values, subject to compatibility and the final quotation.
REPEATED RENTAL OR OWNERSHIP?
Compare your project’s instrument cost.
Enter your equipment and rental quotations. Starting values are illustrative assumptions; calibration, deposits, tax and transport can change the result.
Before specifying CTM-ELV
Will one calibration cover all rope sizes?
No. Different diameters and constructions require appropriate profiles and contact geometry. Provide the complete cable list and request a calibration scope for each combination.
How do we confirm the quoted accuracy?
Agree the range, error definition, reference instrument, rope condition, load points and acceptance limits. A planning target is not a calibration certificate.
Can you review a replacement instrument?
Send the current model, rope profiles, loads, accessories and required data outputs. CTM is independent of the brands mentioned on this site.
GET THE CONFIGURATION RIGHT
Send the rope size. Define the load.
We will review cable construction, measurement range, access and output requirements with your RFQ.