Skip to content
STEEL CABLE & WIRE ROPE INSTRUMENTS Application-led selection · Global B2B inquiries
CTMRIGGING & FORCE INSTRUMENTS
Menu

Aircraft Cable Tensiometer CWT Cable Sizes

Record cable size evidence before specifying a tensiometer.

CWT reference lookup

Record a designation or measured OD. Get a reference and an evidence worksheet.

Cable reference inputs
Lookup mode

0.001–1 in / 0.0254–25.4 mm entry range. Changing the unit reinterprets the entered number. OD alone cannot identify a CWT cable.

Optional evidence & inquiry context

Unit selectors reinterpret the entered number; they do not convert it. Enter the free span in inches. Force entry limits apply to the selected unit and are not physical acceptance limits.

empty

Loading saved worksheet…

—
T5 Table 6 reference only
—
User OD · — mm

A reference pairing is not a tolerance, exact conversion or calibration setting. Source: T5 Rev.25, Table 6 (p.21).

Own legacy cable nomenclature; do not infer force capacity from a CWT label. This record does not determine breaking strength, rigging tension, wear acceptance or airworthiness.

  • Obtain the cable part number and its specification/revision. Measured OD alone cannot identify a CWT designation.
  • Request the applicable AMM task/revision and temperature–tension chart.
  • Request the IPC cable part number and cable certificate/specification.
  • Confirm the instrument model, serial, calibrated cable profile and setup with its manufacturer; no automatic riser or model selection is made.

Published · Sources reviewed . English canonical guide · CTM Rigging & Force Instruments. Next source review by May 2027, or earlier if manufacturer documents change.

1. The decision before choosing a meter

CWT is a legacy hundredweight designation, distinct from measured diameter. A CWT label is a starting reference, not enough information to select a calibrated setup. This page separates three questions: what the cable is, what a manufacturer reference lists, and which configuration the supplier can confirm.

Reference ≠ identity

The T5 table qualifies its pairings; it does not establish an exact conversion.

Use the AMM

Operating tension depends on the applicable maintenance task and conditions.

Confirm the model

CWT coverage is specific to the instrument configuration.

Evidence: T5 Table 6, Tensitron measurement guide, and ACX model table. The tool records missing evidence rather than approving a cable.

2. Designation versus diameter reference

OPTI T5 SOP-TN-001 Rev.25, Table 6, printed page 21 supplies these reference pairings. They are not exact conversions. Decimal inches and millimetres below are arithmetic conversions of the listed fraction, shown to six decimal places, not measured cable dimensions or manufacturing tolerances.

Reference pairing is not cable identification3 and 5 CWT share a reference size3 CWT1/16 inT5 reference only5 CWT1/16 inT5 reference only10 CWT3/32 inT5 reference only15 CWT1/8 inT5 reference onlyMeasured OD → record separately → verify cable P/NSOP-TN-001 Rev.25 Table 6 · not an exact conversion
The shared 1/16-inch reference cannot uniquely identify 3 CWT versus 5 CWT. Do not reverse-match OD to a designation.
T5 Table 6 manufacturer reference — not a cable specification
DesignationT5 reference, inFraction as decimal, inFraction × 25.4, mm
3 CWT1/160.0625001.587500
5 CWT1/160.0625001.587500
10 CWT3/320.0937502.381250
15 CWT1/80.1250003.175000
20 CWT9/640.1406253.571875
25 CWT5/320.1562503.968750
35 CWT3/160.1875004.762500
45 CWT7/320.2187505.556250
70 CWT1/40.2500006.350000
80 CWT9/320.2812507.143750

For actual diameter limits, request the cable specification and revision. A certificate or instrument profile from a different manufacturer must not be treated as evidence that these reference values are interchangeable.

3. What the worksheet does

Tool output and its decision boundary
InputOutputStill unknown
Documented designationT5 Table 6 reference pairingActual OD, construction, cable certificate
Measured OD in inches or mmUnit conversion using 25.4 mm per inchCWT identity, condition and acceptance
Optional tension / temperature / spanEntered context preserved in the recordApproved target and measurement method
Instrument preferenceSupplier review requestCable profile, setup, range and uncertainty

Blank context stays unspecified. Invalid numbers suppress the reference output and identify the field to correct. All calculations run locally; there is no network calculation delay. Reload restores this tab’s validated worksheet when session storage is available. Reset clears the inputs.

4. Documentation request checklist

Build one record for each cable and task. This is an editorial inquiry checklist, not a regulatory release document.

Minimum evidence to request before configuration review
EvidenceWhat to recordIf missing
Cable identityIPC P/N, specification, revision, certificateAsk maintenance records or the cable supplier
Cable geometryMeasured OD + unit; construction, material, jacketRecord unknown; request drawing or inspection details
Aircraft taskAMM task/revision, applicability, ambient conditionsAsk the responsible maintenance authority
InstrumentFull model P/N, serial, card/profile, calibration scopeRequest manufacturer confirmation
InstallationStraight access span, restrictions, measurement locationSupply an installation drawing or photographs
Gather evidence before selecting an instrument1Cable P/N + specMissing? Request evidence.2AMM task + revisionMissing? Request evidence.3Instrument recordsMissing? Request evidence.
Keep evidence gaps visible through the configuration inquiry.

5. Compare instrument evidence, not family names

Manufacturer evidence and configuration limits, checked 2026-11-03
FamilyPublic evidenceRequired follow-up
OPTI T5Riser/card selection is instrument-specificCheck full model and serial-matched card; do not use this pairing as a riser instruction
OPTI T60Manufacturer lists British CWT variants and no alternate risersConfirm exact British variant and its instructions; do not transfer T5 setup
Tensitron ACXACX-250-CWT-1 data sheet lists 5, 10, 15, 20, 25 CWTOther designations need written coverage confirmation
CTM-AIR inquiryConfiguration request onlyConfirm actual cable fit, range, calibration and deliverables in writing

Sources: T5 §3-1, OPTI T60 product documentation, ACX data sheet, page 2. Another manufacturer’s range or certificate does not establish CTM capability.

6. Temperature, access and cable condition

Record ambient temperature, available straight span and jacket condition with the inquiry. The AMM defines the applicable tension requirements; a manufacturer’s measurement instructions define its setup. Tensitron’s guide explains why both cable geometry and ambient conditions matter.

No universal minimum span, thermal force correction, percentage of breaking strength or wear condemnation threshold is assigned here. Inspection and acceptance require the actual approved procedure. Jacket removal, cable replacement and turnbuckle adjustment are outside this lookup.

7. Uncertain identity: an executable next step

If the label, drawing and measured OD disagree, retain all three values without choosing the closest size. Request the cable P/N and specification from maintenance records, then ask the instrument manufacturer which calibration scope applies. Keep the discrepancy in the exported worksheet.

If no records are available, send the measurements, photographs and installation context for documentation review. Do not turn a supplier’s preliminary response into a maintenance release.

8. Three bounded worked cases

Fictional training cases below describe documentation decisions. They do not describe a certified aircraft configuration or maintenance approval.

A. Label available, certificate missing

Premise: A record says 10 CWT; a technician enters 0.106 in OD and 65 lbf requested tension. Both numbers are fictional context.

Process and result: The tool displays the T5 3/32-inch reference separately from 0.106 in / 2.6924 mm measured OD. It makes no fit or wear judgment.

Next action: Request the cable certificate and applicable AMM, then confirm instrument calibration coverage. The designation does not approve 65 lbf.

B. OD available, label missing

Premise: Only a 3.175 mm OD measurement is supplied.

Process and result: OD-only mode returns 0.1250 in and unknown CWT identity. It does not assign 15 CWT from the reference table.

Next action: Obtain the IPC P/N and cable specification before selecting setup.

C. Jacket and access unresolved

Premise: A record says 45 CWT; the cable is jacketed and the available span is recorded as 18 in.

Process and result: The reference can be recorded, while the output asks for an approved measurement method. It calculates no span correction.

Next action: Retain the jacket and request a task-specific method and access review; submit the evidence request without modifying the cable.

Reproduce the worksheet example

Select “Try fictional example” in the lookup. The run below uses 10 CWT, 0.106 in measured OD, 65 lbf requested tension, 68°F and 48 in free span. The output retains the T5 3/32-inch reference separately from the measured 0.106 in / 2.6924 mm OD and lists the documents still needed.

CWT worksheet software run with fictional 10 CWT inputs, separate reference and measured OD, and unresolved documentation steps
Original software capture, 2026-11-03. Fictional inputs; software execution evidence only. No physical cable test, customer result or maintenance approval is represented.

9. Risks and purchasing tradeoffs

Editorial risk review and practical mitigation
RiskDecision impactMitigation / alternative
MisidentificationWrong calibration or replacement assumptionKeep measured OD separate; reconcile P/N and specification
Missing calibration scopeRepeat procurement, downtime or recalibration costRequest an itemised cable/profile schedule before ordering
Restricted access or jacketInstrument cannot be used as expectedReview drawings and task-approved methods before choosing hardware
Incomplete documentationSupplier can only give a provisional responseRequest evidence first; obtain a budgetary review with explicit open items

A familiar instrument may reduce training effort, while a different configuration may require new calibration records and setup review. Compare the complete task and documentation burden. No live stock, price or guaranteed turnaround is claimed.

10. Evidence ledger and limits

Reviewed . Links identify the source used; request the applicable current revision for the supplied instrument.

  • OPTI SOP-TN-001 Rev.25 — Table 6, printed p.21: reference pairings; §3-1, p.6: card and setup. Does not establish a cable manufacturing tolerance.
  • OPTI T60 Series — British variant coverage and architecture. Does not validate another family’s setup.
  • Tensitron ACX data sheet — p.2 model/cable selection. Does not support automatic coverage of every designation on this page.
  • Tensitron measurement guide — aircraft-specific maintenance targets, geometry and temperature context.

Public evidence insufficient: exact cable tolerances, construction-specific breaking strength, allowable wear, installation corrections and CTM profile acceptance. These remain unknown until the responsible source supplies records. The worked cases and purchasing checklist are editorial analysis.

11. Questions before configuration review

Can a CWT label determine operating tension?

No. Obtain the applicable aircraft maintenance task and temperature–tension chart. A designation alone does not establish a rigging target or usable instrument range.

Is the T5 reference table an exact diameter conversion?

No. Its author explicitly qualifies the pairings. Keep the reference, actual measured diameter and cable specification in separate fields.

Can measured OD identify a CWT cable?

No. Size overlap, construction, material, coatings and condition prevent unique identification. The tool converts units and records the measurement without assigning a designation.

Does a reference of 1/8 inch prove 15 CWT identity?

No. It is a manufacturer reference pairing, not a part identification, tolerance or replacement specification. Verify the IPC part number and cable records.

Where should the required tension come from?

Use the applicable AMM task and revision for the aircraft configuration and ambient conditions. A percentage of assumed breaking strength is not supplied here as an alternative.

Does a reference result approve a riser or instrument?

No. It helps locate the correct documents. Setup requires the actual model and its calibration records; changing the instrument dropdown only records an inquiry preference.

Can the tool calculate thermal compensation?

It records temperature only. No verified airframe geometry, cable stiffness, load path or AMM chart is available to calculate a maintenance correction.

Is a short free span automatically acceptable or unacceptable?

This tool makes neither determination. Record the available straight span and obtain the measurement location and setup requirements for the instrument and aircraft task.

Should I strip a jacket to get a reading?

Do not modify a cable based on this page. Record the jacket and request an approved inspection or measurement method from the responsible maintenance authority.

Can the OD entry determine cable wear acceptance?

No. A caliper value alone does not establish the applicable inspection limit, original specification or local damage condition. Use the prescribed inspection procedure.

Are CTM-AIR profiles confirmed for every CWT designation?

No. Cable fit, calibrated force range, uncertainty, profile coverage, documentation, lead time and price require written configuration review.

What if storage, copying or JavaScript is unavailable?

Download the worksheet when copying fails. With JavaScript unavailable, use the table and evidence checklist, then send those details through the contact page or email. Keep a local copy before leaving.

12. Send an evidence request

Use the tool’s inquiry action to carry the full worksheet, original units and missing-evidence list to the existing contact form. Existing inquiry details are retained. Select Reset before entering a real inquiry after viewing a fictional example. Nothing is sent until you submit the contact form.

Or email [email protected] with the evidence checklist. For related tasks, see aircraft control cable tensiometers, calibration card review and the aircraft instrument family.